Sprayfoam

High-performance Spray Polyurethane Foam (SPF) insulation tailored to climate zone, building use, and system interactions. From continuous exterior insulation to targeted cavity fill, we deliver code‑ready assemblies that meet or exceed IECC/ASHRAE and DoD Unified Facilities Guide Specifications. The result: lower utility costs, improved HVAC performance, and a tighter path to mission readiness.

Sprayfoam Building Owner Benefits

Planning
checkbox

Lower energy use and operating cost through high R values and reduced uncontrolled air leakage.

checkbox

Improved comfort and mission readiness via stabilized interior temperatures and fewer drafts.

checkbox

Reduced moisture risk and lifecycle maintenance with durable vapor and air control.

checkbox

Code and federal readiness simplifying procurement, inspections, and acceptance for federal and DoD projects.

checkbox

Fast, professional low‑impact installation with site containment, occupant protection, and adaptable, phased execution.

Key Advantages of Specifying Sprayfoam

Spray Foam (SPF)
R‑Value per inch High (closed‑cell ~6–7) Low (~2.5–3.5) Moderate (~3–4) High nominal but reduced at joints Moderate; lower effective R with seams
Air sealing Monolithic air barrier, SPF is considered an air-barrier material by ABAA No air barrier; gaps common Batt seams allow leakage Requires taped/sealed joints Requires additional sealing at joints
Moisture control Vapor/air control; closed‑cell resists bulk water Wicks moisture; susceptible to dampening Moisture resistant but convective pathways remain Good vapor control but joints vulnerable Water resistant boards; seams can allow migration
Conformity to geometry Seamless on irregular shapes Poor in odd cavities; gaps Better than batts but still fitted Poor for complex geometry Poor for curves; rigid panels require cutting
Thermal bridging mitigation Continuous insulation reduces bridging Stud‑bay thermal bridges persist Similar to batts; bridging remains Improves CI if details tight Requires careful detailing to limit bridging
Structural contribution Adds racking/stiffness (closed‑cell) No structural benefit Minimal structural contribution Rigid but not adhesive to substrate Rigid panels add little substrate adhesion
Durability / Resilience Does not settle or sag; very durable while exposed during construction Can sag and lose R over time Generally stable but can shift Stable if installed correctly Stable but seams may open over time
Installation speed & disruption Fast continuous application; good for phased work Labor intensive in retrofit tight spaces Dense pack can be slow Panel fitting/cutting is time consuming Panel staging and fastening increases time
Performance verification Direct airtightness and thermal continuity validation Hard to verify continuity Verification of continuity difficult Joints require inspection and testing Joints and fastener penetrations complicate QA
Long‑term energy payback Higher upfront cost; faster operational ROI Lower upfront cost; slower payback Moderate payback depending on sealing Payback reduced by joint performance Payback depends on detailing and installation quality
LEED / incentive potential Directly supports air‑sealing and energy credits *Industry Life Cycle Assessment (LCA) provides immediate .5 credit, add to manufacturer-derived credit. Limited for airtightness credits Can help acoustic and fire credits Supports CI/continuous insulation credits if detailed Can support CI credits if continuous and sealed
Limitations Certified, experienced installers and installation temperature/moisture Lower performance; common installation errors; not an air barrier Heavier; installation complexity; not an air-barrier Joints and field seams must be addressed; dimensional stability and facer delamination Seams and fastening require additional detailing; edge/fastener vulnerabilities

DoD analyses and technical reports document significant fuel and energy savings from closed cell SPF in forward deployed and base structures, including rapid ROI and reduced generator fuel use in operational environments.

Why Choose Us

Why Choose 1

Sprayfoam Experience

BEAR delivers proven energy reductions with exceptional SPF installation, lowering peak demand and improved resilience for mission critical facilities.

Why Choose 2

Federal experience

We install to federal and industry (ABAA, SPFA) specification language to streamline procurement and speed your asset’s placement into service.

Why Choose 3

Part of your solution

We are part of the project team working toward project success, our self-performing experience proves we know how to adapt, anticipate and overcome challenges with the team.

Why Choose 4

Risk reduction

Our properly applied SPF insulation adds lifecycle durability to the building; reduces moisture risk, maintenance needs, and lifecycle costs better than competing technologies.

Why Choose 5

Constructability advantage

SPF conforms to irregular substrates and complex details, our experienced teams reduce rework risk and schedule impacts by installing it fast and right the first time.

Why Choose 6

Industry Leadership

BEAR’s principal is a long-time national instructor for the leading SPF and air barrier industry trade associations, maintains installer certifications from both organizations, and oversees installations so they comply with UFC/UFGS, IECC/ASHRAE requirements.

Choosing a professional BEAR LLC installation of Spray Polyurethane Foam will make your building airtight, more resilient, on-schedule, on-budget and mission-ready. Schedule a Capability Briefing, or pre-selection meeting with us to see how we deliver reliable, professional, and amazing results with SPF. Contact us today to begin the conversation.

Claw Outline Blue

BUILDING ENVELOPE ASSESSMENT
AND REPAIR LLC (BEAR)

CAGE: 9CCW2
UEI: KUQQBBMBDTC5

Contact Info

HQ
2290 Technical Parkway, Suite A
N. Charleston, SC 29406

DC
712 H. Street NE, Suite 1331
Washington, DC 20002

CONNECT WITH US

© 2025 Building Envelope Assessment and Repair (BEAR). All Rights Reserved.